The KlassicView Hinged Door offers a range of options including inward and outward orientation, as well as single glazed and double-glazed glass. Available in a single panel hinged door configuration and double panel configuration for French doors, the KlassicView hinged door is water rated with a PA rating of 250*. It also features an in-built fly screen groove that allows for the addition of a fly screen and comes in multiple lock bolting options.

As with all KlassicView systems, the Hinged Door has been tested and exceeds Australian Standard AS2047.

Design Features:

  • null
    Accepts glass thicknesses ranging from 5mm toughened to 10.38mm single glazed glass and 20mm double glazed
  • null
    Water Rated
  • null
    Built-in fly screen groove allows the addition of a fly screen
  • null
    Reversible jamb and head for inward & outward orientation
  • null
    Max panel size 2400mm x 900mm
  • null
    Can be coupled with other KlassicView products with the use of adaptors
  • null
    Outer frame with incorporated fly door track.
  • null
    Multiple bolt locking options available
  • null
    Adjustable Hinges

WERS Ratings

The Window Energy Rating Scheme (WERS) is accredited by the AFRC – which means that WERS ratings are compliant with the NCC.

Reports are prescribed both the window performance for total window U Value (Uw) and total window Solar Heat Gain Coefficient (SHGCw).

U-value

U-value measures how well a product prevents heat from escaping.

It is a measure of the rate of non-solar heat loss or gain through a material or assembly.

U-value ratings generally fall between 2.0-10.0 W/m2.K for Australian products. The lower the U-value, the greater a window’s resistance to heat and cold flow and the better its insulating value.

Solar Heat Gain Co-efficient (SHGC)

SHGC measures how well a product blocks heat caused by sunlight. SHGC is expressed as a number between 0 and 1. The lower a window’s SHGC, the less solar heat it transmits.

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Tested to AS2047

Under the Building Code of Australia, we are required to produce windows and doors that meet mandatory minimum specifications under Australian Standard (AS) 2047 – including AS1288.

Simulations of High Winds and Driving Rains

AS4420.2 Deflection Test – positive and negative wind pressures are applied to the face of the window to test the maximum deflection under wind load.
AS4420.5 Water Penetration Resistance Test – to verify that no water leaks through the window into the building.

Operating Force Requirement

AS4420.3 Operating Force Test – to verify that an opening sash is capable of opening and closing without undue effort.

Air Infiltration Pressure

AS4220.4 Air In filtration Test – the air leakage of a window is tested to ensure energy and acoustic efficiency.

Ultimate Strength Testing

AS4420.6 Ultimate Strength Test – negative and positive wind pressures are applied to the window to at least 1.5 times the design wind pressure to ensure it does not fail in unusual wind conditions.

Download CAD Drawings

Please note: file will be in .zip format.

About KlassicView

About KlassicView

The KlassicView Hinged Door offers a range of options including inward and outward orientation, as well as single glazed and double-glazed glass. Available in a single panel hinged door configuration and double panel configuration for French doors, the KlassicView hinged door is water rated with a PA rating of 250*. It also features an in-built fly screen groove that allows for the addition of a fly screen and comes in multiple lock bolting options.

As with all KlassicView systems, the Hinged Door has been tested and exceeds Australian Standard AS2047.

Design Features:

  • null
    Accepts glass thicknesses ranging from 5mm toughened to 10.38mm single glazed glass and 20mm double glazed
  • null
    Water Rated
  • null
    Built-in fly screen groove allows the addition of a fly screen
  • null
    Reversible jamb and head for inward & outward orientation
  • null
    Max panel size 2400mm x 900mm
  • null
    Can be coupled with other KlassicView products with the use of adaptors
  • null
    Outer frame with incorporated fly door track.
  • null
    Multiple bolt locking options available
  • null
    Adjustable Hinges
Wers Ratings

WERS Ratings

The Window Energy Rating Scheme (WERS) is accredited by the AFRC – which means that WERS ratings are compliant with the NCC.

Reports are prescribed both the window performance for total window U Value (Uw) and total window Solar Heat Gain Coefficient (SHGCw).

U-value

U-value measures how well a product prevents heat from escaping.

It is a measure of the rate of non-solar heat loss or gain through a material or assembly.

U-value ratings generally fall between 2.0-10.0 W/m2.K for Australian products. The lower the U-value, the greater a window’s resistance to heat and cold flow and the better its insulating value.

Solar Heat Gain Co-efficient (SHGC)

SHGC measures how well a product blocks heat caused by sunlight. SHGC is expressed as a number between 0 and 1. The lower a window’s SHGC, the less solar heat it transmits.

I am text block. Click edit button to change this text. Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.

Testing

Tested to AS2047

Under the Building Code of Australia, we are required to produce windows and doors that meet mandatory minimum specifications under Australian Standard (AS) 2047 – including AS1288.

Simulations of High Winds and Driving Rains

AS4420.2 Deflection Test – positive and negative wind pressures are applied to the face of the window to test the maximum deflection under wind load.
AS4420.5 Water Penetration Resistance Test – to verify that no water leaks through the window into the building.

Operating Force Requirement

AS4420.3 Operating Force Test – to verify that an opening sash is capable of opening and closing without undue effort.

Air Infiltration Pressure

AS4220.4 Air In filtration Test – the air leakage of a window is tested to ensure energy and acoustic efficiency.

Ultimate Strength Testing

AS4420.6 Ultimate Strength Test – negative and positive wind pressures are applied to the window to at least 1.5 times the design wind pressure to ensure it does not fail in unusual wind conditions.